Appendix C — Setup Parameters (Fingerprint)
EasyCoder PD41 Printer User’s Guide 73
origin is moved further back from the forward edge of the
copy.
A negative start adjustment means that the specified length of
media will be pulled back before the printing starts. Thus, the
origin is moved towards the forward edge of the copy.
Stop Adjust
The Stop Adjust value is given as a positive or negative number of
dots. Default value is 0, which stops the media feed in a position
suitable for tear off operation.
A positive stop adjustment means that the normal media feed
after the printing is completed will be increased by the
specified value.
A negative stop adjustment means that the normal media feed
after the printing is completed will be decreased by the
specified value.
Media Setup
The media parameters tell the firmware the characteristics of the
media that will be used, so that the printout will be positioned
correctly and attain the highest possible quality.
Media Size
The size of the printable area is defined by three parameters; X-
Start, Width, and Length.
X-Start
Specifies the position of the origin along the dots on the
printhead.
The default X-start value prevents printing outside the labels
when the liner is slightly wider than the labels. If you want to
maximize the print width, reset the X-start value to its default: 0.
By increasing the value for the X-start parameter, the origin will
be moved outwards, away from the inner edge of the media path.
In other words, the larger X-start value, the wider inner margin
and the less available print width.

Table of Contents

Other manuals for Intermec EasyCoder PD41

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Intermec EasyCoder PD41 and is the answer not in the manual?

Intermec EasyCoder PD41 Specifications

General IconGeneral
Print technologyDirect thermal
Maximum resolution203 x 203 DPI
Standard interfacesRS-232, USB 2.0
Internal memory16 MB
Power requirements100-240 VAC ±10%, 45-65 Hz
Media thickness2.3 - 9.8 mm
Maximum label width104 mm
Maximum label length0.15 m
Maximum roll diameter213 mm
Maximum internal memory1 GB
Supported network protocolsTCP/IP, LPR/LPD, FTP, BOOTP, DHCP, HTTP, SNMPv3, SMTP, SNMP-MIB II
Operating temperature (T-T)40 - 104 °F
Operating relative humidity (H-H)20 - 85 %
Weight and Dimensions IconWeight and Dimensions
Depth453 mm
Width273 mm
Height270 mm
Weight13000 g

Related product manuals