Chapter 3 — Developing and Using RFID Applications
72 IF61 Fixed Reader User’s Manual
2 Configure LLRP settings as needed. For help, see the next
table.
To disconnect an existing LLRP connection, click
Te r m i n a t e .
To connect to a remote LLRP client, enter information in
the Reader-Initiated Connections section, and then click
Initiate.
3 Click Activate Changes to save your changes and
immediately make them active.
LLRP Settings Descriptions
Setting Description
Secure Server
Enable
Check this check box to allow connections to the
secure LLRP server on port 5085.
Unsecure Server
Enable
Check this check box to allow connections to the
unsecure LLRP server on port 5084.