Goodrive350 IP55 High-ingress Protection Series VFD Function parameter list
-183-
Function
code
Name
Description
Default
value
Modify
during
undervoltage
stall
P11.20
Integral
coefficient of
current
regulator
during
undervoltage
stall
02000
150
P11.21
Proportional
coefficient of
voltage
regulator
during
overvoltage
stall
01000
60
P11.22
Integral
coefficient of
voltage
regulator
during
overvoltage
stall
01000
10
P11.23
Proportional
coefficient of
current
regulator
during
overvoltage
stall
01000
60
P11.24
Integral
coefficient of
current
regulator
during
overvoltage
stall
02000
250
P11.25
Enable VFD
overload
integral
0: Disable
1: Enable
0
P11.26
Reserved
/
/
/
P11.27
VF vibration
control
method
0x000x11
Ones place:
0: Method 1
1: Method 2
0x00