Goodrive350 IP55 High-ingress Protection Series VFD Function parameter list
-239-
Function
code
Name
Description
Default
value
Modify
output reference
0: Max. value
1: Given value
P90.29
Tension PID
parameter
source
05
0: First group of P90
1: Roll diameter (max. roll diameter)
2: Main reference frequency (max. Frequency)
3: Running linear speed (max. linear speed)
4: Deviation (Reference 100%)
5: Terminal
0
P90.30
Group 1
proportional gain
0.00030.000
0.030
P90.31
Group 1 integral
time
0.0030.00s
5.00s
P90.32
Group 1
differential time
0.0010.00s
0.00s
P90.33
Group 2
proportional gain
0.00030.000
0.030
P90.34
Group 2 integral
time
0.0030.00s
5.00s
P90.35
Group 2
differential time
0.0010.00s
0.00s
P90.36
PID parameter
adjustment
reference point 1
0.0%P90.37
10.0%
P90.37
PID parameter
adjustment
reference point 2
P90.36100.0%
50.0%
P90.38
Min. frequency
for roll diameter
calculation
0.0050.00Hz
0.30Hz
P90.39
Min. linear
speed for roll
diameter
calculation
0.0100.0%
3.0%
P91––Tension control in torque mode
Function
code
Name
Description
Default
value
Modify
P91.00
Tension control
zero speed
reference
01
0: Max. linear speed
1: Max. frequency
0
P91.01
Tension control
zero speed
threshold
0.050.0%
3.0%

Table of Contents