EasyManua.ls Logo

INVT Goodrive350 IP55

INVT Goodrive350 IP55
372 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Goodrive350 IP55 High-ingress Protection Series VFD Basic Operation Instructions
-68-
Function
code
Name
Description
Default
value
P12.03
Rated speed of
asynchronous motor 2
136000rpm
Depend on
model
P12.04
Rated voltage of
asynchronous motor 2
01200V
P12.05
Rated current of
asynchronous motor 2
0.86000.0A
P12.06
Stator resistance of
asynchronous motor 2
0.001–65.53
P12.07
Rotor resistance of
asynchronous motor 2
0.001–65.53
P12.08
Leakage inductance of
asynchronous motor 2
0.16553.5mH
P12.09
Mutual inductance of
asynchronous motor 2
0.16553.5mH
P12.10
No-load current of
asynchronous motor 2
0.16553.5A
P12.15
Rated power of synchronous
motor 2
0.13000.0kW
P12.16
Rated frequency of
synchronous motor 2
0.01HzP00.03 (max. output frequency)
50.00Hz
P12.17
Number of pole pairs of
synchronous motor 2
150
2
P12.18
Rated voltage of
synchronous motor 2
01200V
Depend on
model
P12.19
Rated current of
synchronous motor 2
0.86000.0A
Depend on
model
P12.20
Stator resistance of
synchronous motor 2
0.001–65.53
Depend on
model
P12.21
Direct-axis inductance of
synchronous motor 2
0.01655.35mH
Depend on
model
P12.22
Quadrature-axis inductance
of synchronous motor 2
0.01655.35mH
Depend on
model
P12.23
Counter-emf constant of
synchronous motor 2
010000
300
5.5.7 Start/stop control
The start/stop control of the VFD is divided into three states: start after running command at
power-up; start after restart-at-power-cut function is effective; start after automatic fault reset.
Descriptions for these three start/stop control states are presented below.
There are three start modes for the VFD, which are start at starting frequency, start after DC
brake, and start after speed-tracking. Users can select the proper start mode based on field
conditions.
For large-inertia load, especially in cases where reversal may occur, users can choose to start
after DC brake or start after speed-racking.