Goodrive350 IP55 High-ingress Protection Series VFD Function parameter list
-212-
Function
code
Name
Description
Default
value
Modify
0: No filter
1: Filter
Bit3: Reserved
Bit4: Enable/disable pulse reference filter
0: No filter
1: Filter
Bit5: Pulse reference filter mode (valid when Bit4
is set to 1)
0: Self-adaptive filter
1: Use P20.19 filter parameters
Bit615: Reserved
P20.18
Encoder pulse
filter width
063
0 means 0.25μs
2
P20.19
Pulse reference
filter width
063
0 means 0.25μs
2
P20.20
Pulse number of
pulse reference
065535
1024
P20.21
Enable angle
compensation of
synchronous
motor
01
0
P20.22
Switch-over
frequency
threshold of
speed
measurement
mode
0630.00Hz
1.00Hz
P20.23
Synchronous
motor angle
compensation
coefficient
-200.0200.0%
100.0%
P20.24
Number of pole
pairs in inital
magnetic pole
angle autotuning
1128
2
P21––Position control
Function
code
Name
Description
Default
value
Modify
P21.00
Positioning
mode
0x00000x7121
Ones: Control mode selection (only for FVC)
0: Speed control
1: Position control
Tens: Position command source
0: Pulse train, using PG card terminal (A2, B2)
0x0000