Goodrive350 IP55 High-ingress Protection Series VFD Function parameter list
-189-
P13––Control parameters of synchronous motor
Reduction rate
of the injection
current of
synchronous
motor
0.0%–100.0% rated motor current
Initial pole
detection mode
0: No detection
1: High-frequency current injection
2: Pulse superimposition
Pull-in current is the pole position orientation
current; pull-in current 1 is valid within the lower
limit of pull-in current switch-over frequency
threshold. If users need to increase the starting
torque, increase the value of this function code
properly.
Setting range: 0.0%–100.0% (rated motor
current)
Pull-in current is the pole position orientation
current; pull-in current 2 is valid within the upper
limit of pull-in current switch-over frequency
threshold, and users do not need to change
pull-in current 2 under common situations.
Setting range: 0.0%–100.0% (rated motor
current)
Switch-over
frequency of
pull-in current
0.00Hz–200.0% (of the motor rated current)
High-frequency
superposition
voltage
0.0–300.0% rated motor voltage
Frequency
threshold of
phase-lock loop
switch-in
This parameter is used to set the frequency
threshold for enabling the counter-electromotive
force phase-locked loop in SVC 0. When the
running frequency is lower than the value of this
parameter, the phase-locked loop is disabled;
and when the running frequency is higher than