Goodrive350 IP55 High-ingress Protection Series VFD Function parameter list
-243-
Conversion time
from final zero
bit to initial zero
bit
Feeding interrupt
detection mode
0–3
0: Not detect
1: Detect based on digital value
2: Detect based on roll diameter calculation
value
3: Detect based on feedback position
Feeding interrupt
detection start
delay time
Frequency lower
limit of feeding
interrupt
detection
Error range of
feeding interrupt
detection
Determination
delay time of
feeding interrupt
detection
Handling mode
of feeding
interrupt
0x000–0x111
Ones place: Stop mode
0: Decelerate to stop in emergency manner
1: Coast to stop
Tens place: Alarm mode
0: Stop in enabled stop mode without reporting
an alarm
1: Report an alarm and coast to stop
Hundreds place: Roll diameter memory function
of feeding interrupt
0: Disable
1: Enable
P93––Tension control status viewing
0–3
0: Invalid tension control
1: Close-loop tension speed control