Goodrive350 IP55 High-ingress Protection Series VFD Function parameter list
-244-
Function
code
Name
Description
Default
value
Modify
2: Open loop tension torque control
3: Close-loop tension torque control
P93.01
Actual winding/
unwinding mode
01
0: Winding
1: Unwinding
0
P93.02
Initial roll
diameter
0.05000.0mm
0.0mm
P93.03
Reset roll
diameter
0.05000.0mm
0.0mm
P93.04
Roll diameter
change rate
0.00655.35 mm/s
0.00
mm/s
P93.05
Present roll
diameter
0.05000.0mm
0.0mm
P93.06
Roll diameter for
linear speed
calculation
0.05000.0mm
0.0mm
P93.07
Set linear speed
0.06000.0 m/min
0.0 m/min
P93.08
Present linear
speed
0.06000.0 m/min
0.0 m/min
P93.09
Main reference
frequency
0.00600.00Hz
0.00 Hz
P93.10
Actual
proportional gain
0.0030.00
0.00
P93.11
Actual integral
time
0.0030.00s
0.00s
P93.12
Proportional
output value
065535
0
P93.13
Integral output
value
065535
0
P93.14
PID upper limit
-100.0100.0%
0.0%
P93.15
PID lower limit
-100.0100.0%
0.0%
P93.16
PID output
frequency
-99.9999.99Hz
0.00Hz
P93.17
Main traction
running
frequency
-300.0300.0Hz
0.0Hz
P93.18
Set tension
030000N
0N
P93.19
Tension taper
coefficient
0.0100.0%
0.0%
P93.20
Actual tension
030000N
0N
P93.21
Basic torque
reference value
-300.0300.0%
0.0%
P93.22
Friction
compensation
-300.0300.0%
0.0%

Table of Contents