EasyManuals Logo

INVT Goodrive350 IP55 User Manual

INVT Goodrive350 IP55
372 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #253 background imageLoading...
Page #253 background image
Goodrive350 IP55 High-ingress Protection Series VFD Function parameter list
-244-
Function
code
Name
Description
Default
value
Modify
2: Open loop tension torque control
3: Close-loop tension torque control
P93.01
Actual winding/
unwinding mode
01
0: Winding
1: Unwinding
0
P93.02
Initial roll
diameter
0.05000.0mm
0.0mm
P93.03
Reset roll
diameter
0.05000.0mm
0.0mm
P93.04
Roll diameter
change rate
0.00655.35 mm/s
0.00
mm/s
P93.05
Present roll
diameter
0.05000.0mm
0.0mm
P93.06
Roll diameter for
linear speed
calculation
0.05000.0mm
0.0mm
P93.07
Set linear speed
0.06000.0 m/min
0.0 m/min
P93.08
Present linear
speed
0.06000.0 m/min
0.0 m/min
P93.09
Main reference
frequency
0.00600.00Hz
0.00 Hz
P93.10
Actual
proportional gain
0.0030.00
0.00
P93.11
Actual integral
time
0.0030.00s
0.00s
P93.12
Proportional
output value
065535
0
P93.13
Integral output
value
065535
0
P93.14
PID upper limit
-100.0100.0%
0.0%
P93.15
PID lower limit
-100.0100.0%
0.0%
P93.16
PID output
frequency
-99.9999.99Hz
0.00Hz
P93.17
Main traction
running
frequency
-300.0300.0Hz
0.0Hz
P93.18
Set tension
030000N
0N
P93.19
Tension taper
coefficient
0.0100.0%
0.0%
P93.20
Actual tension
030000N
0N
P93.21
Basic torque
reference value
-300.0300.0%
0.0%
P93.22
Friction
compensation
-300.0300.0%
0.0%

Table of Contents