Goodrive350 IP55 High-ingress Protection Series VFD Function parameter list
-240-
Upper-limit
frequency
source of torque
control
0–3
0: P03.14, P03.15
1: Forward rotation limit set by line speed
2: Reverse rotation limit set by line speed
3: Forward and reverse rotations limit set by line
speed
Running
frequency upper
limit offset of
tension control
Differential
separation
threshold
PID restricts
reverse limit at
zero speed
0–1
0: Enable
1: Disable
Torque
compensation
selection
0x000–0x111
Ones place: Frictional torque compensation
0: No
1: Yes
Tens place: Inertia compensation
0: No
1: Yes
Hundreds place: Compensation direction
0: In line with torque direction
1: Different from torque direction
System
mechanical
parameters
identification
0–2
0: No operation
1: Enable system mechanical inertia
identification
2: Enable mechanical friction torque
identification
Static friction
torque
compensation
coefficient
Sliding friction
torque
compensation
coefficient 1
Sliding friction
torque
compensation
coefficient 2