Goodrive350 IP55 High-ingress Protection Series VFD Function parameter list
-207-
Function
code
Name
Description
Default
value
Modify
regulator output
P18.20
Count value of
resolver
Count value of resolver.
Range: 065535
0
P18.21
Resolver angle
The pole position angle read according to the
resolver-type encoder.
Range: 0.00359.99
0.00
P18.22
Pole angle of
closed-loop
synchronous
motor
Current pole position.
Range: 0.00359.99
0.00
P18.23
State control
word 3
065535
0
P18.24
High bit of count
value of pulse
reference
065535
0
P18.25
Low bit of count
value of pulse
reference
065535
0
P18.26
PG card
measured speed
value
-3276.83276.7Hz
0.0Hz
P18.27
Encoder UVW
sector
07
0
P18.28
Encoder PPR
(pulse-per-
revolution)
display
065535
0
P18.29
Angle
compensation
value of
synchronous
motor
-180.0180.0
0.0
P18.30
Reserved
/
/
/
P18.31
Pulse reference
Z pulse value
065535
0
P18.32
Pulse-given
main control
board measured
speed value
-3276.83276.7Hz
0.0Hz
P18.33
Pulse-given PG
card measured
speed value
-3276.83276.7Hz
0.0Hz
P18.34
Present encoder
filter width
063
0
P18.35
8k test duration
065535
0

Table of Contents