EasyManua.ls Logo

INVT Goodrive350 IP55 - Page 64

INVT Goodrive350 IP55
372 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Goodrive350 IP55 High-ingress Protection Series VFD Basic Operation Instructions
-55-
V /F curve
Straight-type V/F curve
Multi-point V/F curve
Customized V/F curve
Torque-down V/F curve
(power of 2.0)
Torque-down V/F curve
(power of 1.7)
Torque-down V/F curve
(power of 1.3)
PWM output
Frequency setup
Voltage setup
P04.29 voltage acceleration time
P04.30 voltage deceleration time
P04.31 output max. voltage
P04.32 output min. voltage
P00.11 acceleration time 1
P00.12 deceleration time 1
P00.04 running frequency
upper limit
P00.05 running frequency
lower limit
P04.00 Motor 1 V/F curve setup
0
1
2
3
4
5
6
7
8
9
10
Keypad
AI1
PROFIBUS/CANopen/DeviceNet
Modbus/Modbus TCP
PID
Multi-step speed
HDIA
AI3
AI2
Ethernet
HDIB
P04.27(volta
ge setup
channel)
P04.28
0
1
2
3
4
5
6
7
8
9
10
11
Keypad
AI1
PROFIBUS/CANopen/
DeviceNet
Modbus/Modbus
TCP
PID
Multi-step speed
Simple PLC
HDIA
AI3
AI2
Ethernet
HDIB
P00.06
(A frequency
command
selection)
Keypad setting
frequency
P00.10
0
1
2
3
4
5
EtherCAT/PROFINET/EtherNet IP
Programmable card
Pulse train AB
EtherCAT/PROFINET/
EtherNet IP
Programmable
card
11
12
12
13
14
When selecting customized V/F curve function, users can set the reference channels and
acceleration/deceleration time of voltage and frequency respectively, which will form a
real-time V/F curve through combination.
Note: This kind of V/F curve separation can be applied in various frequency-conversion power
sources, however, users should be cautious of parameter setup as improper setup may
damage the machine.

Table of Contents

Related product manuals