Goodrive350 IP55 High-ingress Protection Series VFD Basic Operation Instructions
-58-
7: Modbus/Modbus TCP communication
8: PROFIBUS/CANopen communication
9: Ethernet communication
10: HDIB
11: EtherCAT/PROFITNET/Ethernet IP
communication
12: PLC card
13: Reserved
Set voltage value via
keypad
0.0%–100.0% (rated motor voltage)
Voltage acceleration time
Voltage deceleration time
P04.32–100.0% (rated motor voltage)
0.0%–P04.31 (rated motor voltage)
Flux-weakening coefficient
in the constant power zone
Injection current 1 in
synchronous motor VF
control
When the synchronous motor VF control
mode is enabled, this parameter is used to
set the reactive current of the motor when the
output frequency is lower than the frequency
set in P04.36.
Setting range: -100.0%–+100.0% (of the
motor rated current)
Injection current 2 in
synchronous motor VF
control
When the synchronous motor VF control
mode is enabled, this parameter is used to
set the reactive current of the motor when the
output frequency is higher than the frequency
set in P04.36.
Setting range: -100.0%–+100.0% (of the
motor rated current)
Frequency threshold for
injection current switching in
synchronous motor VF
control
When the synchronous motor VF control
mode is enabled, this parameter is used to
set the frequency threshold for the switching
between input current 1 and injection current
2.
Setting range: 0.0%–200.0% (of the motor
rated frequency)
Reactive current
closed-loop proportional
coefficient in synchronous
motor VF control
When the synchronous motor VF control
mode is enabled, this parameter is used to
set the proportional coefficient of the reactive
current closed-loop control.
Setting range: 0–3000