Loading...
Section E - Hydraulics
Problem Solving
Hydrostatic Transmission
E-65 E-65
9803-9340-8
Pump Pressure Test Points - Series 1
Machines
The upper view shows the top of the pump, the lower view
shows the right hand side of the pump.
!M
WARNING
Fluid Under Pressure
Fine jets of fluid at high pressure can penetrate the
skin. Keep face and hands well clear of fluid under
pressure and wear protective glasses. Hold a piece of
cardboard close to suspected leaks and then inspect
the cardboard for signs of fluid. If fluid penetrates your
skin, get medical
help immediately.
INT-3-1-10_2
707460-1
Fig 6.
A Forward port
B Reverse port
C Forward relief valve
D Reverse relief valve
E Charge relief test point
Ý
ß
Û
Þ
Ü
Û
Ü
Þ

Table of Contents