101
C81 Measuring the adaptor • ange and the zero plane
Options: None
Special function: None
Description:
To keep the machine operative and to allow width measurement in case the
gauge arm is defective, the distance SAPE will be calibrated relative to the
clamping surface of the adaptor on the condition that the gauge arm has
already been calibrated. Having applied the gauge arm to the outer edge
of the adaptor ! ange, press the Acknowledgment key to acknowledge the
input. No further inputs are necessary.
Comments: None.
C82 Calibration of the outer SONAR
Options : None
Special function: None
Description: Before performing the C82, it is mandatory to perform C80 and C81.
1. Mount the calibration rotor with the bracket downward at 6 o’clock.
2. Position the wings of the nut horizontally in order to avoid any
interference with the sonar.
3. Low the wheel guard. Rotate the rotor to place the surface in front of the
sonar.
Raise the wheel guard.
4. Press “RETURN” key to begin the C82.