iSTAR Edge G2 Controller Installation and Configuration Guide 40
Chapter 5 - Controls and Displays
0 Normal operation
1 Display raw card data (slow mode)
2 Display raw card data (fast mode)
3 Display input changes (slow mode)
4 Display input changes (fast mode)
5 Display output changes (slow mode)
6 Display output changes (fast mode)
7 Relay cycle test
8 Hardware test Note: There needs to be an active 6.8.1 ICU for this.
9 Not used
A Not used
B Not used
C Disable watchdog
D Restore Factory Default (reset)
E Not used
F Disable auto-configuration
RM Port Termination Switches
Each of the RM ports has a switch that controls whether there are 120 Ohm RS-485 termination resistors on the iSTAR Edge
G2 end of the RM bus.
Full duplex ports have two termination switches, one for transmission and one for receiving. Half duplex ports have one switch.