6.17.2.2 Battery connector termination plug
The battery connector termination plug is used for single high voltage battery operation. The
termination plug is inserted and fastened to the aircraft side battery connector of the absent
battery.
Figure 6-20 Battery connector termination plug
Can wiring
The sequence of components connected to the CAN does not matter as long as the charge
connector and DCU are at the ends of the daisy chain. The DCU is used to provide ground to
the shielding. The termination resistors are located in the DCU and Charge termination
plug/charger.
CAUTION: It is crucial for the CAN wiring to be shielded all the way to each connector. The
CAN wiring is very susceptible to EMI caused by the motor and motor
controller.
CAUTION: The wires used for the CAN communication should be a shielded twisted pair
that is only grounded at the DCU.