6. Click the big button below Start to initiate the flashing process.
NOTE: It takes up to 10 seconds before information in the footer of the flash magic
window displays the memory address being updated. The initial count-down
during programming is followed by a count-up during the verification process.
7. Reset the main switch after the message "Finished" is displayed in the footer.
Accessing the motor controller parameters
The motor controller needs to be switched on to access it using the N-drive software. This can
be done by switching on the system normally or by using the Maintenance mode.
WARNING: Connecting to the motor controller using N-drive could cause the propeller to
start rotating during connection for a short period. Be sure to always be clear
of the propeller.
1. Switch off the RES main switch.
2. Install both HV batteries.
3. Disconnect the 15 pin D-sub of the motor controller.
4. Connect the adapter to the motor controller and wiring loom of the aircraft:
Figure 9-1 Adapter installation
5. Connect a PC to the adapter using an RS232 to USB cable.
6. Boot the DCU into Maintenance mode.
7. Fully extend the pylon to ensure the propeller clears the front and main doors.
8. Access the setup menu.
9. In the setup menu, scroll to the MotorCtl tab.