8.3  Performance Check
yyyy
yyyy
  [2] TXRX Test 
 
Checks for signals from the scanner. 
 
  Safety Switch      Scanner’s safety switch check 
  AZI Pulse        Scanner rotation signal check 
  HL Pulse        Heading line signal check 
  MH Current       Check on the load current of high voltage in the modulator 
  Trigger        Radar trigger signal check 
 Video       Radar video check 
 
When no abnormality is found, OK is displayed. 
When an abnormality is found, NG is displayed. 
In standby, ** will appear. 
 
 
  [3] Check of Communication Lines (Line Test) 
 
Check the status of communications with options. 
 
  TXRX      Check on connection with the transmitter-receiver 
  SIG.PROC      Check on connection with the signal processing circuit 
  TT       Check on connection with the target tracking unit 
  GYROO I/F      Check on connection with the GYRO I/F unit 
  GPS Compass    Check on connection with the GPS compass 
  ISW      Check on connection with the interswitch 
  Plotter Key      Check on connection with the plotter option 
 
When no abnormality is found, OK is displayed. 
When an abnormality is found, NG is displayed. 
The status display field of equipment not connected is left blank. 
 
 
8 
  [4] Supply Voltage 
 
Check the voltage of internal power supply. 
 
Item  Normal operating range 
12V 11.00-12.20 V 
5V 4.75-5.25 V 
3.3V 3.14-3.46 V 
Battery  2.50 V or more 
 
8-8