ACD320user manual Function parameters list
- 42-
frequency
increment variable
rate
F2.09 AVI lower limit 0.00V~10.00V 0.30V ○ 60
F2.10
AVI lower limit
corresponding
setting
-100.0%~100.0% 0.0% ○ 61
F2.11 AVI upper limit 0.00V~10.00V 9.70V ○ 62
F2.12
AVI upper limit
corresponding
setting
-100.0%~100.0% 100.0% ○ 63
F2.13
AVI input filtering
time
0.00s~10.00s 0.10s ○ 64
F2.14 ACI lower limit 0.00V~10.00V 0.30V ○ 65
F2.15
ACI lower limit
corresponding
setting
-100.0%~100.0% 0.0% ○ 66
F2.16 ACI upper limit 0.00V~10.00V 9.70V ○ 67
F2.17
ACI upper limit
corresponding
setting
-100.0%~100.0% 100.0% ○ 68
F2.18
ACI input filtering
time
0.00s~10.00s 0.10s ○ 69
F2.19
Relay RA/B/C
output selection
0: NO output
1: Frequency reached
2: FDToutput
3: Fault output
4: Motor running forward
3 ○ 70
F2.20
DO (Open circuit
collector ) output
selection
3 ○ 71