253
DG - Diagnostics Parameters (Combivis only)
Value: Description:
53 EiEd - Input Error Detection
54 Eco1 - Error Counter Overrun 1
55 Eco2 - Error Counter Overrun 2
56 Ebr - Error Low Motor Current
57 Eini - Error Initialization MFC
58 EOS - Error Overspeed
59 EHybC - Error Encoder Card Changed
60 ECdd - Error Calculating Motor Data
64 Up Acceleration
65 Up Deceleration
66 Up Constant Speed
67 Down Acceleration
68 Down Deceleration
69 Down Constant Speed
70 No Direction Selected
71 Stall
72 LA Stop
73 Ld Stop
74 Speed Search
75 DC Brake
76 Base Block
77 Low Speed / DC Brake
78 Power Off
79 Quick Stop
80 Hardware Current Limit
81 Search for Reference Active
82 Calculate Motor Data
83 Positioning
84 Low Speed / Power Off
85 Closing Brake
86 Opening Brake
87 Abnormal Stop Overheat Interior
88 No Alarm Overheat Power Module
89 Abnormal Stop Overheat Power Module
90 Abnormal Stop External Fault
91 No Alarm Drive Overheat
92 No Alarm Stop Overheat Interior
93 Abnormal Stop Bus
94 Abnormal Stop Protection Rotation Forward
95 Abnormal Stop Protection Rotation Reverse