258
DG - Diagnostics Parameters (Combivis only)
The Active Prole displays which speed prole is active.
Value: Description:
0 None
1 Inspection
2 High Speed
4 One Floor
8 Emergency
16 Correction
32 Emergency Slowdown
The Active Speed displays which selected speed is active.
Value: Description:
0 None
32 Inspection Speed
64 Leveling Speed
96 Correction Speed
128 High Speed
160 Intermediate Speed 1
256 Earthquake Speed
384 Intermediate Speed 2
512 Emergency Generator Speed
640 Intermediate Speed 3
768 UPS Speed
Displays the car load percentage.
DG52
Active Prole
DG53
Active Speed
DG58
Car Load