259
DG - Diagnostics Parameters (Combivis only)
Displays the motor speed at which the corresponding NTSD input was last
dropped in the corresponding direction.
Displays the total number of runs.
Displays the Calculated Motor Poles based on the following equation:
# of Motor Poles = Rated Frequency (Hz) x 120 / Rated Speed (rpm)
When LE07 = NOP AND LX23 = On With Error this displays the difference
between the learned pole position value and the average.
Displays the value of the internal position counter.
Displays the calculated motor speed while running in open-loop operation.
Displays the calculated elevator speed while running in open-loop
operation.
Displays the signed calculated elevator speed while running in open-loop
operation.
Displays a count of changes in travel direction.
Displays the suggested direction of travel while in UPS mode.
DG63 - 68
NTSD Speed
DG70
Calculated Motor Pole
DG71
Encoder Deviation
DG72
Position Counter
DG75
Motor Speed
(Calculated)
DG76
Elevator Speed
(Calculated)
DG77
Signed Elevator Speed
(Calculated)
DG78
Direction Change
Counter
DG79
Suggested UPS
Direction
DG69
Total Runs

Table of Contents

Other manuals for KEB COMBIVERT F5

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KEB COMBIVERT F5 and is the answer not in the manual?

KEB COMBIVERT F5 Specifications

General IconGeneral
CategoryDC Drives
Enclosure RatingIP20
Control ModeVector Control, V/f Control
ProtectionOvercurrent, Overvoltage, Undervoltage, Overtemperature, Short circuit
Fieldbus CommunicationPROFIBUS, CANopen
Communication InterfacesRS-485
Input Voltage380-480V AC
Cooling MethodForced air cooling (fan)

Related product manuals