Parameter Reference
I = Induction Geared, IX = Induction Gearless, P = PM Geared, PX = PM Gearless
Para. Name
Hex v1.72 Motor/Gear Type
Setting
Options
NUM
Range Units Default
Pass
Level
I IX P PX Min. Max. Imp. Met.
LS15 High Speed Prole
088F -
Prole Setting
Custom
Medium
Soft
Hard
0
1
2
3
- - - -
(0); Custom
+ External
Prole
Basic
Prole Source
External Prole
Internal Prole
0
4
LS16 One Floor Prole
0890 -
Custom
Medium
Soft
Hard
0
1
2
3
- - - - Custom Basic
LS17 Emergency Prole
0891 - Same as LS16 “ “ - - - - Custom Basic
LS20 Acceleration High Speed
0894 0LF51 -
- 0.30 12.00 ft/sec
2
- 2.30
Basic
- 0.091 3.662 - m/s
2
0.701
LS21 Start Jerk High Speed
0895 0LF50 -
- 0.30 32.00 ft/sec
3
- 2.30
Basic
- 0.091 9.759 - m/s
3
0.701
LS22 Accel. Jerk High Speed
0896 0LF52 -
- 0.30 32.00 ft/sec
3
- 2.30
Basic
- 0.091 9.759 - m/s
3
0.701
LS23 Deceleration High Speed
0897 0LF54 -
- 0.30 12.00 ft/sec
2
- 2.30
Basic
- 0.091 3.662 - m/s
2
0.701
LS24 Decel. Jerk High Speed
0898 0LF53 -
- 0.30 32.00 ft/sec
3
- 2.30
Basic
- 0.091 9.759 - m/s
3
0.701
LS25 Stop Jerk High Speed
0899 0LF55 -
- 0.30 32.00 ft/sec
3
- 2.30
Basic
- 0.091 9.759 - m/s
3
0.701
LS27 High Speed Correction
089B - -
- 0.0 6.0 in - 0.0
Basic
- 0.0 15.2 - cm 0.0
LS30 Acceleration One Floor
089E 1LF51 -
- 0.30 12.00 ft/sec
2
- 3.00
Adjuster
- 0.091 3.662 - m/s
2
0.915
LS31 Start Jerk One Floor
089F 1LF50 -
- 0.30 32.00 ft/sec
3
- 3.00
Adjuster
- 0.091 9.759 - m/s
3
0.915
LS32 Accel. Jerk One Floor
08A0 1LF52 -
- 0.30 32.00 ft/sec
3
- 3.00
Adjuster
- 0.091 9.759 - m/s
3
0.915
LS33
Deceleration One Floor /
NTS
08A1 1LF54 -
- 0.30 12.00 ft/sec
2
- 3.00
Adjuster
- 0.091 3.662 - m/s
2
0.915
LS34
Decel. Jerk One Floor /
NTS
08A2 1LF53 -
- 0.30 32.00 ft/sec
3
- 3.00
Adjuster
- 0.091 9.759 - m/s
3
0.915
LS35 Stop Jerk One Floor / NTS
08A3 1LF55 -
- 0.30 32.00 ft/sec
3
- 3.00
Adjuster
- 0.091 9.759 - m/s
3
0.915
LS37
Intermediate Speed 1
Correction
08A5 - -
- 0.0 6.0 in - 0.0
Adjuster
- 0.0 15.2 - cm 0.0
LS38
Intermediate Speed 2
Correction
08A6 - -
- 0.0 6.0 in - 0.0
Adjuster
- 0.0 15.2 - cm 0.0
LS40 Acceleration Emergency
08A8 2LF51 -
- 0.30 12.00 ft/sec
2
- 1.50
Adjuster
- 0.091 3.662 - m/s
2
0.460
LS41 Start Jerk Emergency
08A9 2LF50 -
- 0.30 32.00 ft/sec
3
- 1.50
Adjuster
- 0.091 9.759 - m/s
3
0.460
LS42 Accel. Jerk Emergency
08AA 2LF52 -
- 0.30 32.00 ft/sec
3
- 1.50
Adjuster
- 0.091 9.759 - m/s
3
0.460
LS43 Deceleration Emergency
08AB 2LF54 -
- 0.30 12.00 ft/sec
2
- 1.50
Adjuster
- 0.091 3.662 - m/s
2
0.460
LS44 Decel. Jerk Emergency
08AC 2LF53 -
- 0.30 32.00 ft/sec
3
- 1.50
Adjuster
- 0.091 9.759 - m/s
3
0.460
LS45 Stop Jerk Emergency
08AD 2LF55 -
- 0.30 32.00 ft/sec
3
- 1.50
Adjuster
- 0.091 9.759 - m/s
3
0.460

Table of Contents

Other manuals for KEB COMBIVERT F5

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KEB COMBIVERT F5 and is the answer not in the manual?

KEB COMBIVERT F5 Specifications

General IconGeneral
CategoryDC Drives
Enclosure RatingIP20
Control ModeVector Control, V/f Control
ProtectionOvercurrent, Overvoltage, Undervoltage, Overtemperature, Short circuit
Fieldbus CommunicationPROFIBUS, CANopen
Communication InterfacesRS-485
Input Voltage380-480V AC
Cooling MethodForced air cooling (fan)