322
Parameter Reference
I = Induction Geared, IX = Induction Gearless, P = PM Geared, PX = PM Gearless
Para. Name
Hex v1.72 Motor/Gear Type
Setting
Options
NUM
Range Units Default
Pass
Level
I IX P PX Min. Max. Imp. Met.
DG50 Elevator Speed
11B2h LF90
RO RO RO RO
- -
0 2000 ft/min - 0
0.000 10.160 - m/s 0.000
DG51 Mode
11B3h
RO RO RO RO
See Section 6.16 - 0 65535 - - 0
DG52 Active Prole
11B4h
RO RO RO RO
None
Inspection
High Speed
One Floor
Emergency
Correction
Emergency Slowdown
0
1
2
4
8
16
32
0 65535 - - 0
DG53 Active Speed
11B5h
RO RO RO RO
None
Inspection Speed
Leveling Speed
Correction Speed
High Speed
Intermediate Speed 1
Earthquake Speed
Intermediate Speed 2
Emergency Generator Speed
Intermediate Speed 3
UPS Speed
0
32
64
96
128
160
256
384
512
640
768
0 65535 - - 0
DG54 Leveling Distance
11B6h
RO RO RO RO
- -
0.0 18.0 in - 0.0
0.0 45.7 - cm 0.0
DG55 Target Floor
11B7h
RO RO RO RO
- - 0 64 - - 0
DG56 Current Floor
11B8h
RO RO RO RO
- - 0 64 - - 0
DG57 Next Avail. Floor
11B9h
RO RO RO RO
- - 0 64 - - 0
DG58 Car Load
11BAh
RO RO RO RO
- - -100 100 % 0
DG59 Brake Release Time
11BBh
RO RO RO RO
- - 0.00 5.00 sec 0.00
DG60 Average Regen Power
11BCh
RO RO RO RO
- - 0.0 3000.0 kW 0.0
DG61 Peak Regen Power
11BDh
RO RO RO RO
- - 0.0 3000.0 kW 0.0
DG62 Runs Per Hour
11BEh
RO RO RO RO
- - 0 500 - - 0
DG63 NTSD Speed 1 Up
11BFh
RO RO RO RO
- ft/min m/s -
DG64 NTSD Speed 2 Up
11C0h
RO RO RO RO
- ft/min m/s -
DG65 NTSD Speed 3 Up
11C1h
RO RO RO RO
- ft/min m/s -
DG66 NTSD Speed 1 Down
11C2h
RO RO RO RO
- ft/min m/s -
DG67 NTSD Speed 2 Down
11C3h
RO RO RO RO
- ft/min m/s -
DG68 NTSD Speed 3 Down
11C4h
RO RO RO RO
- ft/min m/s -
DG69 Total Runs
11C5h
RO RO RO RO
- 0
DG70 Calculated Motor Pole
11C6h
RO RO RO RO
- -
DG71 Encoder Deviation
11C7h
RO RO RO RO
- -
DG72 Actual Position
11C8h
RO RO RO RO
- 0
DG73 Lift App Control Word
11C9h
RO RO RO RO
- -
DG75 Motor Speed (Calculated)
11CBh
RO RO RO RO
- - 1/min 1/min -
DG76
Elevator Speed
(Calculated)
11CCh
RO RO RO RO
- - ft/min m.s -
DG77
Signed Elevator Speed
(Calculated)
11CDh
RO RO RO RO
- - ft/min m/s -
DG78 Direction Change Counter
11CEh
RO RO RO RO
- - - - -
DG79 Suggested UPS Direction
11CFh
RO RO RO RO
- - - - -
DG93 Fault Log (Count)
11DDh
RO RO RO RO
- - - - -
DG94 Fault Log (Timestamp)
11DEh
RO RO RO RO
- - - - -
DG99 Last Fault
11E3h
RO RO RO RO
- - - - -
DB00 Lift Time
- - - - - -
DB01 DIN/Switch/ServSLV Time
- - - - - -
DB02 Lift Com Time
- - - - - -
FB01 Field Bus Control Word
1281
RO RO RO RO
- - 0h FFFFh - - - OEM