210 Keysight E5092A ENA Series Configurable Multiport Test Set
Post-Repair Procedures
Post-Repair Procedures
6-
Switch 9 (20GHz
SPDT Pin Switch
Module)
(P9397-60001)
Not adjustment
needed
Perform the following performance tests.
- Write SN
- Load Match, Insertion Loss and
Isolation Test for Switch 9 (SPDT, 9COM,
9A and 9B)
- LED Check
- DCBUS Check
Switch 10 (20GHz
SPDT Pin Switch
Module)
(P9397-60001)
Not adjustment
needed
Perform the following performance tests.
- Write SN
- Load Match, Insertion Loss and
Isolation Test for Switch 10 (SPDT,
10COM, 10A and 10B)
- LED Check
- DCBUS Check
Switch 1 (20GHz
SP4T Pin Switch
Module)
(P9398-60001)
No adjustment
needed
Perform the following performance tests.
- Write SN
- Load Match, Insertion Loss and
Isolation Test for Switch 1 (SP4T, Port1,
1A, 1B, 1C and 1D)
- LED Check
- DCBUS Check
Switch 2 (20GHz
SP4T Pin Switch
Module)
(P9398-60001)
No adjustment
needed
Perform the following performance tests.
- Write SN
- Load Match, Insertion Loss and
Isolation Test for Switch 2 (SP4T, Port2,
2A, 2B, 2C and 2D)
- LED Check
- DCBUS Check
Table 6-1 Post-Repair Procedures
Replaced
Assembly or Part
Required
Adjustments
Correction Constants
(CC)
Verification