Kinco FD3&CD3 User Manual
Table 4-2: EASY menu parameters
For a new motor controller, the set motor type is “00” and “3030” appears
at the LED display. If the new motor controller is connected to a valid
motor, the motor type is auto-recognized and saved.
The motor type saved in the controller and the connected motor type are
compared later on. If they are different, “FFFF” flashes at the LED display.
The user needs to confirm the EA01 value, save motor data and reboot the
controller to eliminate this state.
Examples of motor type, motor code and EA01 display value.
Motor type Motor code/ LED display
AAK/LED JAK/LED KAK/LED
SMH40S-0010-30xxx-4LKH KY/594B JY/594A MY/594D
SMH40S-0005-30xxx-4LKH KZ/5A4B JZ/5A4A MZ/5A4D
SMH60S-0020-30xxx-3LKH K0/304B
SMH60S-0040-30xxx-3LKH K1/314B
The command type affects controller-internal interface settings, the initial
operation mode after power on and the default settings for DIN- and OUT
functions (refer to table 4-3).
0: CW/CCW pulse train mode Operation mode = -4
1: P/D pulse train mode Operation mode = -4
2: A/B phase control master / slave mode Operation mode = -4
6: Analog velocity mode by AIN1 Operation mode = -3
7: Analog velocity mode by AIN2 Operation mode = -3
8: Communication
9: Position table mode Operation mode = 1
Used when EA02 is set to 0-2.
By default, the display shows the values in decimal format. If the number is
greater than 9999, the display is in hexadecimal format.
Used when EA02 is set to 6 or 7.
The relationship between analog input voltage and motor velocity the unit
of measure is rpm/V.
For controller use with standard KINCO-AS motors, the maximum value is
374, the maximum velocity is 3740rpm/10v/.
For more details see chapter 9.3 (d3.29).
1.Load type
2.Application
3.Limit switch
4. Alarm output
polarity
The meaning of each digit of the LED display from right to left.
(1) Load type, influences the control loop.
0: No load
1: Belt drive
2: Ball screw
(2) Application, influences the control loop.
0: P2P
1: CNC
2: Master / slave mode
(3) Limit switch.
0: Controller default
1: Delete the limit switch function