Kinco FD3&CD3 User Manual
(4) Polarity of OUT5
0: Normally closed contacts
1: Normally open contacts
Write “1” to save control and motor parameters.
Write “2” to save control and motor parameters and reboot the servo.
Write “3” to reboot the servo.
Write “10” to initialize the control parameters.
Notice:
Users must save control and motor parameters and reboot the controller
after changing the motor type in EA01.
After saving the parameters, the servo will set the control loop parameters
according to the load type and application.
As a result of setting the command type in EA02, the digital I/O configuration of the controller is defaulted
differently, depending on the command type setting as shown in the following table:
Table 4-3: The default settings related to EA02
Analog Input for Velocity Control