Kinco FD3&CD3 User Manual
61
Table 6-5: Common parameters
Panel
address
Internal
address
Type
Name
Description
6083.00
Uint32
Profile_Acc
Profile acceleration, profile deceleration, for
Operation_Mode 1 and 3
6084.00
Uint32
Profile_Dec
d2.24
6080.00
Uint16
Max_Speed_RPM
Maximal speed (unit: rpm)
d3.16
2020.0D
Int8
Din_Mode0
If Operation Mode Sel function is configured to DIN,
Operation_Mode(6060.00)=Din_Mode0 when
Din_Internal=0; Operation_Mode=Din_Mode1 when
Din_Internal=1
d3.17
2020.0E
Int8
Din_Mode1
6073.00
Uint16
CMD_q_Max
Output current limit
6040.00
Uint16
Controlword
0x0F/0x2F: Enable the controller for Operation_Mode 3, -
3, -4, 4 and for Position Table mode
0x2F->0x3F: Activate absolute position command for
Operation_Mode 1
0x4F->0x5F: Activate relative position command for
Operation_Mode 1
0x0F->0x1F: Start homing for Operation_Mode 6
0x06->0x86: Reset the controller error
0x06: Disable the controller
6060.00
Int8
Operation_Mode
-3: Instantaneous velocity mode
3: Profile velocity mode
1: Position mode
-4: Pulse train mode
4: Torque mode
Information
Operation_Mode itself is not savable, however, it is set in accordance with the settings in the
Command_Type(3041.02) or EA02 in the EASY panel menu to a suitable value (see table 4-2
for EA02). Alternatively, Operation_Mode can be configured to be settable and/or switchable by
the DIN function Operate_Mode_Sel (see table 5-2).
Step 4: Save and reboot
See chapter 5.
Step 5: Start operation
Start operation via DIN or PC software.
Information
The DIN function has highest priority the object value can not be modified manually
anymore if it’s configured in DIN, e.g. if the enable function is configured,
Controlword(6040.00) cannot be modified manually via PC software.