Chapter 4 Menu operations MDC-2200/2500 Series
0093125002-05 4-50
(5) FTC manual selection
Not in use. Do not change setting value. Initial value is “1”.
(6) Main Bang Suppression
Suppress surrounding image of nearby own ship due to own pulse to make image easier to observe.
Note: Too high setting value may delete image of nearby own ship.
(7) Target level
Set up video signal level of ATA.
(8) ATA Performance (Details in development)
This is to select the optimum tracking characteristics (calculation process) depending on the purpose of
usage, to make the best of the ATA performance.
Select the most suitable setting to the behavior of own ship or target.
Note: This is currently not in use as ATA software is in development.
(9) Video mode
Change expression of radar image.
4 types of video mode (0 to 4) are provided. (Initial value “4”)
“0” is wide gradation and good resolution for short range.
“1” is narrower gradation than that of “0”.
“2” is narrower gradation than that of “1”.
“3” is narrower gradation than that of “2” and is high sensitive mode.
“4” is high resolution in short range and high gain in long range.