8.14 =filten
8.14.1 Description
This command sets whether or not the final output filter is enabled on the output data. This
only applies to the final filtering prior to data output and does not change the intermediate
anti-aliasing filter operation or any the other internal filtering used.
NOTE: KVH recommends that users should not operate the unit with the filter disabled as they can expect
aliasing of the output data. This may especially be a problem when using the delta-velocity and delta-angle type of
outputs as the, possibly noisy computed value will be applied over the entire output period. This does not change
filter coefficients or filter types, so they can be disabled and enabled. Like most other commands, this configuration
is saved in non-volatile memory and recalled on power-up.
8.14.2 Usage
=FILTEN,<0|1>
8.14.3 Response
FILTEN,<0|1>
8.15 ?filten
8.15.1 Description
This command queries whether the filter is enabled on the output data.
8.15.2 Usage
?FILTEN
8.15.3 Response
FILTEN,<0|1>