This document contains proprietary information of KVH Industries, Inc. and neither this document nor said proprietary information shall be
published, reproduced, copied, disclosed, or used for any purpose without the express written permission of a duly authorized KVH
representative.
8.41 ?volt
8.41.1 Description
This command is a diagnostic query that returns the available primary supply voltages on the
system. It might be run at the request of sales/service and is not typically needed by a user.
8.41.2 Usage
?VOLT
8.41.3 Response
VOLT,[1 Volt],[3 Volt],[5 Volt]
[1 Volt] indicates the voltage on an internal 1.2V supply.
[3 Volt] indicates the voltage on an internal 3.3V supply.
[5 Volt] indicates the voltage on an internal 5.0V supply.
All values are returns as ASCII strings representing float values.
Example response with approximate typical values:
VOLT,1.187,3.307,4.974
8.42 ?ws
8.42.1 Description
This is a diagnostic command to query the software versions of the various internal
programmable devices. It is intended for software update utility programs to determine existing
versions for field firmware update purposes. Normally users do not need to operate this
command. Software versions relate to internal programmable devices including DSPs and
FPGAs.
8.42.2 Usage
?ws
8.42.3 Response
1775 IMU
ICB DSP Rev [ICB DSP Revision Letter] Version: [ICB DSP Version Number]
ICB FPGA Rev: [ICB FPGA Hexadecimal Version Number]
GCB DSP Rev [GCB DSP Revision Letter] Version: [GCB DSP Version Number]
GCB FPGA Rev: [GCB FPGA Revision Letter]