56-0298 Rev. B
This document contains proprietary information of KVH Industries, Inc. and neither this document nor said proprietary information shall be
published, reproduced, copied, disclosed, or used for any purpose without the express written permission of a duly authorized KVH
representative.
Page 50 of 77
8.35 =rstcfg
8.35.1 Description
This command resets all configuration settings back to the factory defaults. The settings
include the output data rate, filter settings, output units, axes, etc. (See Section 10 for the
settings that are reset to defaults.) This is similar to asserting the Configuration Reset signal on
the Micro-D Interface.
Errata Note: in Rev. B software and earlier, this command also defaults the serial
communications baud rate. If necessary, users will have to adjust host communications to the
default baud and then reprogram the baud back to the desired value after issuing this
command.
8.35.2 Usage
=RSTCFG
8.35.3 Response
RSTCFG
8.36 ?temp
8.36.1 Description
This command query returns the main temperature sensor of the system as an integer string.
The units returned depend on the configuration defined by the =TEMPUNITS command.
8.36.2 Usage
? TEMP
8.36.3 Response
TEMP,[Temperature Value]
Example, temperature in degrees C for 45
o
C:
TEMP,45
Example, temperature in 100ths of degrees C for 45.02
o
C:
TEMP,4502