EasyManuals Logo

Lantronix EMG 8500 User Manual

Lantronix EMG 8500
482 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #458 background imageLoading...
Page #458 background image
17: Command Reference
EMG™ Edge Management Gateway User Guide 458
Description
Sets the acceptable range for the internal temperature sensor (an SNMP trap is sent if the
temperature is outside of this range). Temperatures can be entered in either Celsius or
Fahrenheit; to indicate a temperature is Fahrenheit, append the degrees with an ‘F’, i.e., “75F”.
Parameter
set temperature <one or more parameters>
Parameters: low <Low Temperature in C. or F.>
high <High Temperature in C. or F.>
calibrate <Temperature Calibration in C. or F.|cancel>
Note: The calibration offset will be applied one hour after setting the value.
Description
Displays the acceptable range and the current reading from the internal temperature sensor.
show temperature
Syntax
show temperature
Description
Shows the temperature.
Xmodem Commands
set xmodem repo
Syntax
set xmodem repo import <Xmodem File> via <ftp|sftp|scp>
host <IP Address or Name> login <User Login>
[path <Path to Xmodem File>]
set xmodem repo rename <Xmodem File> newfile <New Filename>
set xmodem repo delete <Xmodem File>
Description
Manages a repository of files that can be sent to or received from a device port with Xmodem,
Ymodem, or Zmodem. The maximum file size is 20 MB, and the maximum total repository size is
25 MB.

Table of Contents

Other manuals for Lantronix EMG 8500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lantronix EMG 8500 and is the answer not in the manual?

Lantronix EMG 8500 Specifications

General IconGeneral
BrandLantronix
ModelEMG 8500
CategoryGateway
LanguageEnglish

Related product manuals