10: USB Port
SLC™ Console Manager User Guide 154
IP Settings
4. Click Apply.
Restart Delay The number of seconds after the timeout and before the SLC console manager
attempts another connection. The default is 30 seconds.
CBCP Server Allow
No Callback
For CBCP Server state, allows "No Callback" as an option in the CBCP
handshake in addition to User-defined Number and Admin-defined Number.
CBCP Client Type For CBCP Client, this selects the number that the client would like to use for
callback - either a user-defined number passed to the server (specified by the
Fixed Dial-back Number) or an administrator-defined number determined by
the server based on the login that is PAP or CHAP authenticated.
Service The available connection services for this modem port (Telnet, SSH, or TCP).
Only one can be active at a time. The default is None.
Telnet Port Telnet Port Telnet session port number to use if you selected Telnet.
Defaults:
USB Port U1: 2049
USB Port U2: 2050
Range: 1025-65535
SSH Port The SSH session port number to use if you selected SSH.
Defaults:
USB Port U1: 3049
USB Port U2: 3050
Range: 1025-65535
TCP Port The TCP (raw) session port number to use if you selected TCP.
Defaults:
USB Port U1: 4049
USB Port U2: 4050
Range: 1025-65535
Authenticate
(checkbox)
If selected, the SLC unit requires user authentication before granting access to
the port. Authenticate is selected by default for Telnet Port and SSH Port, but
not for TCP Port.