3: Installation
SLC™ Console Manager User Guide 33
mounted IEC-type AC power connector(s) are provided for universal AC power input (North
American cord provided).
The SLC0xx12N models have a single supply/input, while the SLC0xx22N models have dual
inputs and dual supplies. The power connector also houses a replaceable protective fuse
(fast-blow 4.0A, maximum 250V AC) and the on/off switch. In addition, we provide the
SLC0xx22N with a “Y” cord. See the SLC models listed in Table 3-2 on page 30.
Figure 3-4 shows the AC power inputs and power switch.
Figure 3-4 AC Power Input and Power Switch (SLCxxxx2N)
Note: The SLC48 console manager with dual AC does not have an on/off switch.
DC Input
The DC version of the SLC console manager accepts standard –48 VDC power. The SLC0xx24T
models accept two DC power inputs for supply redundancy. Lantronix provides the DC power
connections using industry standard Wago connectors. One set of connectors is included with the
SLC console manager. You can order additional connectors (part number 721-103/031-000) from
the Wago catalog at http://www.wagocatalog.com/okv3/index.asp?lid=1&cid=1&str_from_home=first
.
Figure 3-5
shows the DC power inputs and power switch.
Figure 3-5 DC Power Inputs and Power Switch (SLCxxx24T)

Table of Contents

Other manuals for Lantronix SLC8

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lantronix SLC8 and is the answer not in the manual?

Lantronix SLC8 Specifications

General IconGeneral
BrandLantronix
ModelSLC8
CategoryServer
LanguageEnglish

Related product manuals