116
1..............
2..............
3..............
4..............
5..............
6..............
7..............
8..............
9..............
F461/2
Conguration
The programming procedure is performed using a standard touch tone telephone, connected
to the RJ8 socket of the actuator, using the appropriate cable, supplied as standard.
LIGHTING MODE
In this mode the two relays can be enabled independently, and can also be programmed
with different functions.
A user can be activated with “impulsive” monostable operation using relay 1 (Example
1: timed switching on of the staircase light), and with “ON/OFF” bistable operation using
relay 2 (Example: boiler activation/deactivation).
TEMPERATURE CONTROL MODE
This mode enables to combine the telephone actuator to the operation of the BTicino
timer thermostat, item HC/HS/HD/L/N/NT4451 and item AM5721.
Using this mode, it is possible to remotely change the operation of the timer thermostat.
If the timer thermostat is in any AUTO, MAN, ANTIFREEZE, PARTY, HOLIDAY, or OFF
condition, by activating the following controls on the actuator:
- ANTIFREEZE, the timer thermostat will switch to the antifreeze condition, until an
unlocking command is received;
- AUTO, the timer thermostat will switch to the automatic condition.
AUTOMATISM MODE
In this mode, the two relays are both controlled using the same command and cannot be
activated independently from each other.
Therefore, when relay 1 is programmed, the actuator will automatically also manage
relay 2.
The AUTOMATISM mode is recommended for controlling users interlocked with each other,
such as the operation of a rolling shutter (up/down), motors (forward/backwards), etc.
For more details see the instruction leaflet supplied with the device.
The actuator can be programmed to operate in three different modes:
- lighting: to enable or disable lights, boilers, etc.;
- automation: to activate the rolling shutter motors (closing – opening), or other motors;
- temperature control: to activate or deactivate the heating or the air conditioning
system to be used with the BTicino timer thermostat item HC/HS/HD/L/N/NT4451 and
item AM5721.
Also, in the three operating modes the two relays can themselves be programmed to
operate with the monostable function (once timed, the relay closes for the programmed
time; ideal, for example, when timed switching on of the staircase lights is required), or
bistable (ON - OFF, at every command the relay changes its status and keeps it until a new
command is received, behaving as a switch).
The actuator can also be connected to an internal telephone extension (shunted), when
a PABX BTicino telephone switchboard is present (to expand the number of relays that
can be selected remotely); it is also possible to connect in parallel to each other on the
same telephone line up to 4 actuators, even if an answering machine is also installed.
At the end of each programming operation the actuator sends to the telephone receiver a
confirmation (programming correct) or an error (programming failed) tone.
To program the telephone actuator move
the selector (3) to “PROG”, and enter the
commands on the telephone connected to
the connector (4). The programming cable
is supplied as standard.
Telephone actuator
MQ00380-b-EN 22/04/2014