5.2308.8512.0 B
4-6 DESCRIPTION AND OPERATION
The concentrate feeder sends output to the T4C farm management
software.
4.2.3.1 ADS3830 PCB
The ADS3830 PCB (see figure 8 on page 4-7) controls the valves that
supply air to the cylinders of the feed dosing unit. The pcb is installed in
the control box.
The control software that runs on the pcb communicates with the T4C
farm management software. The status indicator (9) displays the status.
Connector J604 (10) is connected to the valves for the cylinders that move
the feed dosing units. Connector J602 (12) is connected to the photocell,
if applicable.
The following table shows the connector/pin - cylinder combinations:
Connector
Pins
Component
J602
In4, gnd Photocell (Qwes IR models
only)
J603
In5, gnd, 24V
Magnet sensor up
In6, gnd, 24V Magnet sensor down
J604
Out1, gnd
Dosing unit 1
Out2, gnd Dosing unit 2 (optional)
Out3, gnd Dosing unit 3 (optional)
Out4, gnd Dosing unit 4 (optional)
J605
Out8, gnd Pneumatic cylinder M-box
innovators in agriculture