•166-904-001:IMMI2CTestFailed
IMMIndicatesfailureinPCA9543--2-ChannelI2CSwitchbus(BUS3).
Recoverable
No
Severity
Error
Serviceable
Yes
Automaticallynotifysupport
No
UserResponse
Performtheactionsmentionedoneatatimeandtrythetestaftereachaction:
1.Turnoffthesystemanddisconnectitfrompower.Waitfor45seconds.Reconnectittopower.
2.MakesurethatDSAandBMC/IMMareatthelatestlevel.
3.Runthetestagain.
4.Iffailureremains,referto"Troubleshootingbysymptom"inthesystem"InstallationandService
Guide"forthenextcorrectiveaction.
Relatedlinks
–LenovoSupportwebsite
–LatestlevelofDSA
–LatestlevelofBMC/IMM
•166-905-001:IMMI2CTestFailed
IMMIndicatesfailureinMAX7319--I2CPortExpanderbus(BUS4).
Recoverable
No
Severity
Error
Serviceable
Yes
Automaticallynotifysupport
No
UserResponse
Performtheactionsmentionedoneatatimeandtrythetestaftereachaction:
1.Turnoffthesystemanddisconnectitfrompower.Waitfor45seconds.Reconnectittopower.
2.MakesurethatDSAandBMC/IMMareatthelatestlevel.
3.Runthetestagain.
4.Iffailureremains,referto"Troubleshootingbysymptom"inthesystem"InstallationandService
Guide"forthenextcorrectiveaction.
Relatedlinks
1098LenovoSystemx3550M5InstallationandServiceGuide