Lenovo System x3550 M5 - Removing the Serveraid Adapter Memory Module

Lenovo System x3550 M5
1144 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SAS/SATA signal
cables
SAS/SATA power cable
SAS/SATA power
connector
SAS/SATA
configuration
connector
SAS/SATA power cable
Figure115.ServeRAIDadaptercableroutingfortwelve2.5-inchhot-swapharddiskdriveconfiguration
Step8.ConnectthesignalcablestotheSAS/SATAadapter.
Step9.Reconnectanycablesthatyouremoved.
Step10.ReplacePCIriser-cardassembly1ifyouhaveremoveditearlier(see“ReplacingaPCIriser-card
assembly”onpage172).
Step11.Reinstallthecover(see“Replacingthecover”onpage120).
Step12.Turnontheperipheraldevicesandtheserver.
Step13.ImportyourRAIDconfigurationtothereplacementServeRAIDadapteras
aforeignconfiguration.SeetheServeRAID-MSoftwareUserGuideat
https://www-947.ibm.com/support/entry/portal/docdisplay?lndocid=migr-5086126for
instructions.
Note:Whenyourestarttheserver,youarepromptedtoimporttheexistingRAIDconfigurationtothe
newServeRAIDadapter.
RemovingtheServeRAIDadaptermemorymodule
UsethisinformationtoremovetheServeRAIDadaptermemorymodule.
ToremovetheServeRAIDadaptermemorymodule,completethefollowingsteps:
Chapter5.Removingandreplacingcomponents191