EasyManua.ls Logo

Lenovo System x3550 M5 - Chapter 2. Configuring; Updating the Firmware

Lenovo System x3550 M5
1144 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter2.Configuring
Thischapterprovidesinformationaboutupdatingthefirmwareandusingtheconfigurationutilities.
Updatingthefirmware
Usethisinformationtoupdatethefirmware.
Important:
Someclustersolutionsrequirespecificcodelevelsorcoordinatedcodeupdates.Ifthedeviceispart
ofaclustersolution,verifythatthelatestlevelofcodeissupportedfortheclustersolutionbeforeyou
updatethecode.
Beforeyouupdatethefirmware,besuretobackupanydatathatisstoredintheTrustedPlatformModule
(TPM),incaseanyoftheTPMcharacteristicsarechangedbythenewfirmware.Forinstructions,seeyour
encryptionsoftwaredocumentation.
Installingthewrongfirmwareordevice-driverupdatemightcausetheservertomalfunction.Beforeyou
installafirmwareordevice-driverupdate,readanyreadmeandchangehistoryfilesthatareprovided
withthedownloadedupdate.Thesefilescontainimportantinformationabouttheupdateandthe
procedureforinstallingtheupdate,includinganyspecialprocedureforupdatingfromanearlyfirmwareor
device-driverversiontothelatestversion.
YoucaninstallcodeupdatesthatarepackagedasanUpdateXpressSystemPackorUpdateXpressCD
image.AnUpdateXpressSystemPackcontainsanintegration-testedbundleofonlinefirmwareand
device-driverupdatesforyourserver.UseUpdateXpressSystemPackInstallertoacquireandapply
UpdateXpressSystemPacksandindividualfirmwareanddevice-driverupdates.Foradditionalinformation
andtodownloadtheUpdateXpressSystemPackInstaller,gototheToolsCenterforSystemxand
BladeCenterathttps://support.lenovo.com/us/en/documents/LNVO-CENTERandclickUpdateXpress
SystemPackInstaller.
Whenyouclickanupdate,aninformationpageisdisplayed,includingalistoftheproblemsthattheupdate
fixes.Reviewthislistforyourspecificproblem;however,evenifyourproblemisnotlisted,installingthe
updatemightsolvetheproblem.
Besuretoseparatelyinstallanylistedcriticalupdatesthathavereleasedatesthatarelaterthantherelease
dateoftheUpdateXpressSystemPackorUpdateXpressimage.
ThefirmwarefortheserverisperiodicallyupdatedandisavailablefordownloadontheLenovoWebsite.To
checkforthelatestleveloffirmware,suchastheUEFIfirmware,devicedrivers,andintegratedmanagement
module(IMM)firmware,gotohttp://www.ibm.com/support/fixcentral.
Downloadthelatestfirmwarefortheserver;then,installthefirmware,usingtheinstructionsthatareincluded
withthedownloadedfiles.
Whenyoureplaceadeviceintheserver,youmighthavetoupdatethefirmwarethatisstoredinmemoryon
thedeviceorrestorethepre-existingfirmwarefromaCDorDVDimage.
Thefollowinglistindicateswherethefirmwareisstored:
UEFIfirmwareisstoredinROMonthesystemboard.
IMM2.1firmwareisstoredinROMonthesystemboard.
EthernetfirmwareisstoredinROMontheEthernetcontrollerandonthesystemboard.
©CopyrightLenovo2016,2017