Step5.AlignthememorymodulewiththeconnectorontheServeRAIDadapterandpushitintothe
connectoruntilitisfirmlyseated.
ServeRAID adapter
ServeRAID
memory module
Retention
bracket
Figure117.ServeRAIDmemorymoduleinstallation
Step6.ReinstalltheServeRAIDSAS/SATAcontroller(see“ReplacingaServeRAIDSAS/SATAcontroller”
onpage185).
Step7.Reconnectthepowercordsandanycablesthatyouremoved.
Step8.Reinstallthecover(see“Replacingthecover”onpage120).
Step9.Slidetheserverintotherack.
Step10.Turnontheperipheraldevicesandtheserver.
Removingathermalkit(hot-swapfan)
Usethisinformationtoremoveathermalkit(hot-swapfan).
Attention:Itisnotnecessarytodisconnectthepowerwhenremovingthehot-swapfan.Toensureproper
serveroperation,replaceafailedhot-swapfanwithin30seconds.
Toremoveahot-swap-fan,completethefollowingsteps:
Step1.Readthesafetyinformationthatbeginson“Safety”onpagevand“Installationguidelines”on
page116.
Step2.Removethecover(see“Removingthecover”onpage119).
Chapter5.Removingandreplacingcomponents193