Alerts(in-bandandout-of-bandalerting,PETtraps-IPMIstyle,SNMP,e-mail)
AutoBootFailureRecovery(ABR)
Automaticmicroprocessordisableonfailureandrestartinatwo-microprocessorconfigurationwhenone
microprocessorsignalsaninternalerror.Whenoneofthemicroprocessorsfail,theserverwilldisablethe
failingmicroprocessorandrestartwiththeothermicroprocessor.
AutomaticServerRestart(ASR)whenPOSTisnotcompleteortheoperatingsystemstopsresponding
andtheoperatingsystemwatchdogtimertimes-out.TheIMMmightbeconfiguredtowatchforthe
operatingsystemwatchdogtimerandrestartsthesystemafteratimeout,iftheASRfeatureisenabled.
Otherwise,theIMMallowstheadministratortogenerateanonmaskableinterrupt(NMI)bypressingthe
NMIbuttonforanoperating-systemmemorydump.ASRissupportedbyIPMI.
Avirtualmediakey,whichenablesremotepresencesupport(remotevideo,remotekeyboard/mouse,
andremotestorage).
Bootsequencemanipulation
Command-lineinterface
Configurationsaveandrestore
DIMMerrorassistance
TheUnifiedExtensibleFirmwareInterface(UEFI)disablesafailingDIMMthatisdetectedduringPOST,
andtheIMMlightstheassociatedsystemerrorLEDandthefailingDIMMerrorLED.
Environmentalmonitorwithfanspeedcontrolfortemperature,voltages,fanfailure,powersupplyfailure,
andpowerbackplanefailure.
IntelligentPlatformManagementInterface(IPMI)SpecificationV2.0andIntelligentPlatformManagement
Bus(IPMB)support.
Invalidsystemconfiguration(CONFIG)LEDsupport
Localfirmwarecodeflashupdate
Nonmaskableinterrupt(NMI)detectionandreporting
Operating-systemfailurebluescreencapture
PCIconfigurationdata
Power/resetcontrol(power-on,hardandsoftshutdown,hardandsoftreset,schedulepowercontrol)
Querypower-supplyinputpower
ROM-basedIMMfirmwareflashupdates
SerialoverLAN(SOL)
Serialportredirectionovertelnetorssh
SMIhandling
Systemeventlog(SEL)-userreadableeventlog
TheIMM2.1alsoprovidesthefollowingremoteservermanagementcapabilitiesthroughtheipmitool,
managementutilityprogram:
Command-lineinterface(IPMIShell)
Thecommand-lineinterfaceprovidesdirectaccesstoservermanagementfunctionsthroughtheIPMI
2.0protocol.Usethecommand-lineinterfacetoissuecommandstocontroltheserverpower,view
systeminformation,andidentifytheserver.Youcanalsosaveoneormorecommandsasatextfileand
runthefileasascript.
SerialoverLAN