Recoverable
No
Severity
Event
Serviceable
No
Automaticallynotifysupport
No
Relatedlinks
LenovoSupportwebsite
LatestlevelofDSA
LatestlevelofBMC/IMM
180-801-000:Check-pointPanelTestAborted
Check-pointPanelTestAborted.BMCisunabletoverifythattheoperatorinformationpanelcableis
connected.
Recoverable
No
Severity
Warning
Serviceable
Yes
Automaticallynotifysupport
No
UserResponse
Completethefollowingsteps:
1.Inspectandreseatoperatorinformationpanelcableatbothends.
2.VerifythattheBaseboardManagementController(BMC)isworking.
3.Runthetestagain.
4.Iffailureremains,referto"Troubleshootingbysymptom"inthesystem"InstallationandService
Guide"forthenextcorrectiveaction.
Relatedlinks
LenovoSupportwebsite
LatestlevelofDSA
LatestlevelofBMC/IMM
180-901-000:Check-pointPanelT estFailed
Check-pointPanelTestFailed.Operatorreportedincorrectdisplay.
Recoverable
No
Severity
AppendixC.DSAdiagnostictestresults969