Step 3. Connect the signal and power cables to the drive assembly. See Chapter 6 “Internal cable routing”
on page 145
.
After you finish
1. Complete the parts replacement. See
“Complete the parts replacement” on page 143.
2. Check the drive activity LED on the front of the server to verify if the drives are operating correctly. See
“Front view” on page 11 .
3. Use the Lenovo XClarity Provisioning Manager Lite to configure the RAID if necessary. For more
information, see
https://pubs.lenovo.com/lxpm-lite/RAID_setup.
Remove the drive cage (bay 0-1)
Follow instructions in this section to remove the bay 0 drive cage or bay 1 drive cage.
S002
CAUTION:
The power-control button on the device and the power switch on the power supply do not turn off the
electrical current supplied to the device. The device also might have more than one power cord. To
remove all electrical current from the device, ensure that all power cords are disconnected from the
power source.
About this task
Attention:
• Read
“Installation Guidelines” on page 29 and “Safety inspection checklist” on page 30 to ensure that you
work safely.
• Power off the server and peripheral devices and disconnect the power cords and all external cables. See
“Power off the server” on page 34.
• Remove any locking device that secures the server, such as a Kensington lock or a padlock.
• Place the server on its side with the cover up.
Procedure
Step 1. Make preparation for this task.
a. Remove the server cover. See
“Remove the server cover” on page 135.
Attention: The heat sink and processor could be very hot. To avoid burning yourself, wait for a
few minutes after turning off the server before you remove the server cover.
b. Remove the simple-swap drive from drive bay 0 or drive bay 1. See “Remove a simple-swap
drive (bay 0-1)” on page 38
.
Step 2. Remove the bay 1 drive cage.
Note: Remove the bay 1 drive cage first; then, proceed to remove the bay 0 drive cage.
a.
Slightly pull out the latch on the bay 1 drive cage to release it from the bay 0 drive cage.
b.
Pull the bay 1 drive cage out from the chassis.
Chapter 5. Hardware replacement procedures 47