Attention:
Read
“Installation Guidelines” on page 29 and “Safety inspection checklist” on page 30 to ensure that you
work safely.
Touch the static-protective package that contains the component to any unpainted metal surface on the
server; then, remove it from the package and place it on a static-protective surface.
Procedure
Step 1. Make sure the cage bar is installed in the chassis. To install the cage bar, see
“Install the server
cover” on page 137
.
Step 2. (Optional) Install the EMI shield included in the component packaging to the chassis.
Note: Installing the EMI shield is required when the original shield slot on the chassis is vacant.
a.
Insert the tabs on the left end of the EMI shield into the shield slot on the chassis.
b.
Push the EMI shield into the chassis until it snaps into place.
Figure 63. Installing the EMI shield
Step 3. Make sure there is no optical drive installed on the optical drive cage. Then, Install the optical drive
cage to the bay 2 drive cage.
a.
Align the four hooks on the optical drive cage with the corresponding hooks on the bay 2
drive cage; then, lower the optical drive cage onto the bay 2 drive cage, and slide the optical
drive cage forward until it secures into place.
Note: Make sure the four hooks on both drive cages are fully engaged.
b.
Fasten the screw to secure the two drive cages together.
Chapter 5. Hardware replacement procedures 81