TheDesktopManagementInterface(DMI)mustbeupdatedwhenthesystemboardisreplaced.Usethe
AdvancedSettingsUtility(ASU)toupdatetheDMIintheUEFI-basedserver.TheASUisanonlinetoolthat
supportsseveraloperatingsystems.Makesurethatyoudownloadtheversionforyouroperatingsystem.
YoucandownloadtheASUfromthewebsite.TodownloadtheASUandupdatetheDMI,completethe
followingsteps.
Note:Changesaremadeperiodicallytothewebsite.Theactualproceduremightvaryslightlyfromwhatis
describedinthisdocument.
1.DownloadtheAdvancedSettingsUtility(ASU):
a.Gotohttp://www.lenovo.com/support.
b.ClicktheDownloadstabatthetopofthepanel.
c.UnderToolsCenter,selectViewToolsCenterdownloads.
d.SelectAdvancedSettingsUtility(ASU).
e.ScrolldownandclickthelinkanddownloadtheASUversionforyouroperatingsystem.
2.ASUsetstheDMIintheIntegratedManagementModule(IMM).Selectoneofthefollowingmethodsto
accesstheIntegratedManagementModule(IMM)tosettheDMI:
Onlinefromthetargetsystem(LANorkeyboardconsolestyle(KCS)access)
Remoteaccesstothetargetsystem(LANbased)
BootablemediacontainingASU(LANorKCS,dependinguponthebootablemedia)
Note:Lenovoprovidesamethodforbuildingabootablemedia.Youcancreateabootablemedia
usingtheBootableMediaCreator(BoMC)applicationfromtheToolsCenterWebsite.Inaddition,
theWindowsandLinuxbasedtoolkitsarealsoavailabletobuildabootablemedia.Thesetoolkits
provideanalternatemethodtocreatingaWindowsProfessionalEditionorMasterControlProgram
(MCP)basedbootablemedia,whichwillincludetheASUapplication.
3.CopyandunpacktheASUpackage,whichalsoincludesotherrequiredfiles,totheserver.Makesure
thatyouunpacktheASUandtherequiredfilestothesamedirectory.Inadditiontotheapplication
executable(asuorasu64),thefollowingfilesarerequired:
ForWindowsbasedoperatingsystems:
ibm_rndis_server_os.inf
device.cat
ForLinuxbasedoperatingsystems:
cdc_interface.sh
4.AfteryouinstallASU,TypethefollowingcommandstosettheDMI:
asusetSYSTEM_PROD_DATA.SysInfoProdName<m/t_model>[access_method]
asusetSYSTEM_PROD_DATA.SysInfoSerialNum<s/n>[access_method]
asusetSYSTEM_PROD_DATA.SysEncloseAssetTag<asset_tag>[access_method]
Where:
<m/t_model>
Theservermachinetypeandmodelnumber.Typemtmxxxxyyy,wherexxxxisthemachinetype
andyyyistheservermodelnumber.
<s/n>
Theserialnumberontheserver.Typesnzzzzzzz,wherezzzzzzzistheserialnumber.
<asset_method>
Theserverassettagnumber.Typeassetaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa,where
aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaistheassettagnumber.