Step7.Updatetheserverconfiguration(see“Updatingtheserverconfiguration”onpage81).
Step8.Slidetheserverbackintotherack,ifnecessary.
Step9.Starttheserver.Confirmthatisstartscorrectlyandrecognizesthenewlyinstalleddevices,and
makesurethatnoerrorLEDsarelit.
Step10.(BusinessPartnersonly)Completetheadditionalstepsin“InstructionsforBusinessPartners”
onpage21.
Note:Remembertoroutethepowercordthroughthecableretainerclipsothatitdoesnot
accidentallybecomedisconnected.
000000000
000000000
000000000
000000000
Figure65.Powercord
Installingtheairbaffle
Usethisinformationtoinstalltheairbaffle.
Toinstalltheairbaffle,completethefollowingsteps:
Step1.Readthesafetyinformationthatbeginsonpage“Safety”onpagevand“Installationguidelines”
onpage30.
Step2.Lowertheairbaffleintotheserver.Makesurethatthetabsontheairbaffleareinsertedintothe
holesonthechassis.
Attention:Forpropercoolingandairflow,replacetheairbafflebeforeyouturnontheserver.
Operatingtheserverwiththeairbaffleremovedmightdamageservercomponents.
74LenovoSystemx3650M4BDInstallationandServiceGuide