Youcansolvesomeproblemsbycomparingtheconfigurationandsoftwaresetupsbetweenworkingand
nonworkingservers.Whenyoucompareserverstoeachotherfordiagnosticpurposes,considerthem
identicalonlyifallthefollowingfactorsareexactlythesameinalltheservers:
Machinetypeandmodel
UEFIfirmwarelevel
IMMfirmwarelevel
Adaptersandattachments,inthesamelocations
Addressjumpers,terminators,andcabling
Softwareversionsandlevels
Diagnosticprogramtypeandversionlevel
Setuputilitysettings
Operating-systemcontrol-filesetup
SeeAppendixD“Gettinghelpandtechnicalassistance”onpage899
forinformationaboutcallingLenovo
forservice.
Recoveringtheserverfirmware
Usethisinformationtorecovertheserverfirmware.
Important:Someclustersolutionsrequirespecificcodelevelsorcoordinatedcodeupdates.Ifthedevice
ispartofaclustersolution,verifythatthelatestlevelofcodeissupportedfortheclustersolutionbefore
youupdatethecode.
Iftheserverfirmwarehasbecomecorrupted,suchasfromapowerfailureduringanupdate,youcan
recovertheserverfirmwareineitheroftwoways:
In-bandmethod:Recoverserverfirmware,usingeitherthebootblockjumper(AutomatedBoot
Recovery)andaserverFirmwareUpdatePackageServicePack.
Out-of-bandmethod:UsetheIMMWebinterfacetoupdatethefirmware,usingthelatestserver
firmwareupdatepackage.
Notes:Youcanobtainaserverupdatepackagefromoneofthefollowingsources:
DownloadtheserverfirmwareupdatefromtheWorldWideWeb.
Contactyourservicerepresentative.
TodownloadtheserverfirmwareupdatepackagefromtheWorldWideWeb,goto
http://www.lenovo.com/support.
Theflashmemoryoftheserverconsistsofaprimarybankandabackupbank.Youmustmaintainabootable
SystemxServerFirmware(serverfirmware)imageinthebackupbank.Iftheserverfirmwareintheprimary
bankbecomescorrupted,youcaneithermanuallybootthebackupbankwiththebootblockjumper,orin
thecaseofimagecorruption,thiswilloccurautomaticallywiththeAutomatedBootRecoveryfunction.
In-bandmanualrecoverymethod
Torecovertheserverfirmwareandrestoretheserveroperationtotheprimarybank,completethefollowing
steps:
Step1.Turnofftheserver,anddisconnectallpowercordsandexternalcables.