EasyManua.ls Logo

Lenovo x3650 M4 BD 5466 - Memory Problems

Lenovo x3650 M4 BD 5466
934 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Memoryproblems
FollowthesuggestedactionsintheorderinwhichtheyarelistedintheActioncolumnuntiltheproblemis
solved.
SeeChapter5“Partslisting”onpage141
tocheckifacomponentisaconsumable,structural,orFRUpart.
Ifanactionstepisprecededby“(Trainedtechnicianonly),thatstepmustbeperformedonlybyatrained
technician.
SymptomAction
Theamountofsystemmemory
thatisdisplayedislessthan
theamountofinstalledphysical
memory.
Note:Ifyouchangememory,youmustupdatethememoryconfigurationinthe
Setuputility.
1.Makesurethat:
NoerrorLEDsarelitontheoperatorinformationpanel,onthememorytray,
orontheMAX5memoryexpansionmodule.
Memorymirroringdoesnotaccountforthediscrepancy.
Thememorymodulesareseatedcorrectly(see“Removingamemory
module”onpage177
and“Replacingamemorymodule”onpage178).
Youhaveinstalledthecorrecttypeofmemory.
Ifyouchangedthememory,youupdatedthememoryconfigurationinthe
Setuputility.
Allbanksofmemoryareenabled.Theservermighthaveautomatically
disabledamemorybankwhenitdetectedaproblem,oramemorybank
mighthavebeenmanuallydisabled.
2.CheckthePOSTeventlog:
IfaDIMMwasdisabledbyasystems-managementinterrupt(SMI),replace
theDIMM.
IfaDIMMwasdisabledbytheuserorbyPOST,runtheSetuputilityand
enabletheDIMM.
3.Runmemorydiagnostics(see“RunningtheDSAPrebootdiagnosticprograms”
onpage119).
4.Makesurethatthereisnomemorymismatchwhentheserverisattheminimum
memoryconfiguration(see“Memorymoduleinstallation”onpage55for
informationaboutDIMMrulesandpopulationsequence).
5.ReseattheDIMM.
6.Restarttheserver.
MultiplerowsofDIMMsina
branchareidentifiedasfailing.
1.ReseattheDIMMs;then,restarttheserver.
1.Removethelowest-numberedDIMMpairofthosethatareidentifiedand
replaceitwithanidenticalpairofknowngoodDIMMs;then,restarttheserver.
Repeatasnecessary.Ifthefailurescontinueafterallidentifiedpairsare
replaced,gotostep4.
2.ReturntheremovedDIMMs,onepairatatime,totheiroriginalconnectors,
restartingtheserveraftereachpair,untilapairfails.ReplaceeachDIMMin
thefailedpairwithanidenticalknowngoodDIMM,restartingtheserverafter
eachDIMM.ReplacethefailedDIMM.Repeatstep3untilyouhavetestedall
removedDIMMs.
3.Replacethelowest-numberedDIMMpairofthoseidentified;then,restartthe
server.Repeatasnecessary.
4.(Trainedtechnicianonly)Replacethesystemboard.
126LenovoSystemx3650M4BDInstallationandServiceGuide

Table of Contents